What makes this monitor switcher and controller different from just about all the others we carry is the inclusion of a DA converter which allows you monitor both analog and digital signals through the same 2RU box.
Dangerous Monitor features
- Analog input switching
- 3 pairs of analog inputs
- Digital input switching: 4 digital inputs, with active thru outputs
- Onboard D/A: Custom Troisi converter
- Full console monitoring functions: L&R Phase reverse, L&R Mute, Mono, Dim, Alternate Speaker, and -6 VU Meter Offset
- Analog and digital meter feeds
- Stepped attenuator volume control for precise adjustment and repeatability
- Optional remote
SPECIFICATIONS
- Frequency Response: 1 Hz-100 kHz within 0.2 dB
- Total Harmonic Distortion: 0.003% in audio band
- Intermodulation Distortion: 0.002% IMD60 4:1
- Converter Lock Range: 32 kHz - 96 kHz
- Converter THD+Noise: 0.002%
- Crosstalk @ 1 kHz: -113 dB
- Crosstalk @ 10 kHz: -102 dB
- Noise floor: -91 dBu total energy in audio band
- Max level: +26 dBu
- Nominal operating level: +4 dBu
- Input impedance: 25k ohm balanced
- Output impedance: 50 ohm balanced (600 ohm drive capable)
- Gain accuracy: better than .05 dB @ 1 kHz for any gain setting
- Power consumption: 40 watts
- Size: 2 RU for Monitor, 1 RU for power supply
Home | Gear | This Just In! | Swag | The Black Pages
|
|